On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. After connecting the device, the flow led flashes for one minute and turns off. So changed out the motor with a Century model. My pool guy went directly to saying I need a new one. The Pool is a Roman 23 in ground. If this is an ABG pool, check the skimmer hose and adapter fittings. Hi Anessa, Hayward VS pumps are known to have Drive Errors, whereas Pentair, I dont hear so many problems about the Intelliflo. Hi Tony, yes if the impeller spins freely then the shaft does too (unless you are unthreading the impeller from a stationary shaft) normally. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. Could this be an issue with my pump? If you havent inspected your cell yet, now is aperfect time. Hi Patrick, so you have power from the breaker to the timer and to the switch. If recalibrating your salt level did not resolve your problem, then your cell or your PCBoard is bad and needs replacing. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. Third, is that breakers sometimes dont last forever, and can be go bad, usually after 20-30 yrs tho. Today two years later, same company opened pool,pump stuck and want to install another 3400vsp for $1330. If power is reaching the motor, but nothing (no noise), look for any disconnected or severed wires in the back (shut off power first), if nothing, the motor may be dead. "logo": {
), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. They function as the starting battery for the motor, to help it get up to speed quickly. Thank You, Thank You, Thank You! Inspect the capacitor, or have it tested, or just replace with same MFD rating shown. Hi Rachel, when there is no sound at all i would check the circuit breaker to be sure it is on. I suspect a loose wire, or mis-wiring or other simple fix. If your pump is made of plastic, it must be the bearings, failing so hard that it is causing the motor to overheat. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. So we cannot manually rotate the shaft a full revolution. "@type": "ImageObject",
I just got my home back, I walked outside and pool level was well below jets. It got very wet and tripped the breaker. For the filter, its a common problem, but its usually solved with soaking the fingers in a DE filter cleaner solution, or acid. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. Hi, each pool filter system has a different pressure, but if there was a normal pressure, many systems are designed to run around 10 psi (clean). Water began flowing out the pump motor and it tripped the gfci. The pump is working fine, however only the low speed is working. When I checked it again, the shaft (impellers) spin freely when tested by hand, but its not actually spinning when powered up? Open the door and inspect for debris with a mirror and flashlight. I have a 2 HP Hayward two speed pump that is on its second season. I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. Third possibility is just that the pump capacitor is bad, if the motor wont turn over, wont spin. Learn more about pool care and repair. Everything coming in appears to be tight. Hope that helps! Davy, When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. No special tools or lube needed. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. I have a new above ground pool with a Hayword pump. Although in low speed, chlorine is not generated so not sure why even run the low speed. This troubleshooting guide should give you all the tools and understanding you need to tackle any issue with your Hayward pool pump with confidence! There should be no continuity. Not normal, but cant see a reason why that would cause the seal to fail. The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. 3 things are key, 1. The pipe from the pump is connected to the valve in the port labeled PUMP and the pipe returning to the pool connects to the port labeled RETURN. Recently when power came on it hums and shuts down after 6 seconds. I tried replacing that oring and the leak got worse somehow and it just doesnt feel like there is any pressure when tightening the 6 bolts that hold the pump and motor together. I primed the pump and was ready to add DE compund. Hi Rose, Its common that winterized pumps may freeze up, caused by a rust layer inside the motor. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. My pump just quit working, figured it was old so I replaced the motor. registration, authorized Check all the power wires for tight fit and no corrosion. If pressure is lower than normal check for air leak on the suction side of the pump, or a clogged impeller, or low water level, stuck skimmer weir, or closed suction valves. It could also be the centrifugal switch located in the rear of the motor, on the end of the shaft, check for looseness, broken spring or other damage. I hadnt run my pumps in a couple of weeks. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have We would like to show you a description here but the site wont allow us. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. Turned it off tho clear the skimmer basket.. water level is correct. Poor connection inside the plug or socket. Same thing if I try to backwash. Hi Davy. OR actually, since you say that it starts good and then loses flow that would be different probably an air leak in front of the pump (pump lid, or the pipe coming into the pump, or leaky suction side valve), or a stuck skimmer weir blocking water flow, or low water level causing a vortex in the skimmer. Please note the breaker is not tripped. Check the breaker inside the house, make sure its not tripped. hopefully. Or is it coincidence that I have a bad line in the pool. Click Here to View Replacement Aquarite Parts 25 This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. High will run fine but next day I have to do the same, start with low and switch to high. We have tried switching outlets and that sometimes works. The pump is currently configured for 115v. Hi Christy, there may be a GFCI test button that popped, on an outlet below the breaker box, or on a light pole? "wordCount": "1009",
Hoses popping off could also indicate a high pressure problem after the filter, such as obstructed return lines, such as plugged or blocked wall returns, or closed valves. Nothin seems to be leaking anywhere. Replace with the exact same MFD number capacitor if defective (they can be tested) the capacitor is the battery that starts the motor. Use a Drain King to pressurize the pipe backwards, to remove such clogs. It is a generic Hayward pump with 1 HP. Bump shaft or diaphragm gasket? Hi, thats strange! Once it finishes calibrating, cycle the Main Switch from AUTO to SUPER CHLORINATE and back to AUTO. My question to you is what to do from here. It can also be a loose pump lid allowing air to creep in around the o-ring. Hi Dave, check that the centrifugal switch is screwed on tightly to the end of the motor shaft. Thinking of switching to PentAir, I hear they are better built. If a LED is flashing, wait 60 seconds after starting the filter pump. Hi Don, when its not an air leak, pump surging will then be an obstruction in the pipe, or filter, heater, check valve/filter valve/diverter valve, a bit of plastic usually (once I found a golf ball, in the skimmer pipe), that is pulled into a 90 or up against a port that is too small for the obstruction to pass. You will have a choice of replacing the bearings or having a local electric motor shop do it, or replace the entire motor, or the entire pump. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. High water flow (>125 gpm) into the heater. Hi Davy! Inspect for any damage to wires or wire casing. The pump has power, turns on, and seals are tight, however it will not cycle the water. My pump is one horse power. In some cases, a small bit of debris (stick or sand) can become lodged between the gasket and the rotor (aka diverter or footpad) and can cause leakage. First time pool owner (obviously dont know what we are doing). Hi Jason, I would wait to spend the money, until certain that would be the fix. My pool is running, with water flow. A new o-ring may be needed. Hi Sal, for the pump lid, it may help to close the incoming and outgoing valves, and open the filter air bleeder, to release the suction. Automatic reset is 60 minutes. Replumb your flow switch if it does not meet the distance requirements. Is the water level ok in the pool, and the skimmer weir is not stuck? Hi Tom, if it is the same exact pump and pump size, that would be unusual, but if its the same horsepower, but a different pump model, that would be the simplest answer. Thanks Pump is sitting about 3 feet below level of water in pool..maybe a bit more. Inspect the motor shaft for any obstructions. This occurred after a lengthy power outage. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). Heres a link to the Hayward Heater Owners Manual, which may be helpful. Just started getting a No Flow error. The pump was working well since opening the pool in May, but the last few days it was quite weak. Tried again and again to start, but just keep hearing a click sound and nothing happens. And if you have Hayward heater error codes on display, that makes finding the problem almost easy! Thanks for the help. Could also be a loose wire connection, the power wires. If it sounds loud and grumbly, that can be a sign of cavitation, being starved for water, from not enough water being supplied (it wants more). There should be NO elbow after the flow switch. Work through the list below if your Hayward pool heater is on the fritz. Before I purchase all new control board assembly, does this sound about right? The other rectifier is rated as 18-33 VDC. I didnt plug the line and got a lot of water on the pump motor. Thanks. more, View In this Pool Care Basics Video, we discuss how to clean a salt cell. We believe it needs a new seal. I was only able to read and yes feel voltage in the pool when the main pump was running only. This year, I have replaced all the plumbing from the pump to the filer. During that time, the pump got really hot and melted the fitting on the top. I think the problem is a nick in the face of the salt cell that the unions o-ring seals against, but I cant feel anything there so its not like a giant burr or anything. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. After just a few minutes the flow slows down to almost nothing. On a Hayward pump with clogged impeller, you can remove the basket, reach through the small hole with your fingers (pump off! Any suggestions? You could also check incoming voltage, and wire connections, as fluctuating current can cause an overheated motor, but if its very old, it may just be on its way out, sorry to say at which point you could replace just the motor and shaft seal, or the entire pump. Then, take a look at the capacitor, located at 9 oclock. switch and to the capacitor, to be sure nothing is loose or no crimped wires. Just be sure to buy the correct seal for your make/model pump, for the Powerflo Matrix pump, thats here: https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c SPX1250XZ2C. I would inspect it for corrosion, wire tightness, water damage or insect damage. So you could cut off the pipe and cap it yes, although it might be worth investigating the repair cost the crack could be just 2 foot below the ground, near the pump/filter. Do you think the motor is fried as a result of no water running thru? However, when I check the connection at the wired, there is definetly juice there. Well it so happens that I am having the exact same issue with the new cell. Hi Ernesto, hmmm, Im not quite sure, but sounds like it could be either low voltage, or a loose connection, or something mis-wired between the terminal board and the capacitor? Before you test your capacitor, take note of its appearance. Hi Doug, could be a bad breaker, or bad wiring between the pump and breaker. The shaft turned with zero resistance. Any thoughts? Also check that the ground wire is firmly attached at both ends, on the motor and the plug. Internal electrical faults in the pump, such as a short circuit or improper ground, also can cause the device to draw more power than necessary and excess heating. If you have a multiport valve, set it on Recirculate, to bypass the filter, and rule out any problems there. Breakers do wear out, especially if used often as the pump switch. fingers crossed, as we say. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. It could be air in the pump, or it could be that the pump is too big (powerful) for the number of pipes. Any ideas? Thanks, Checked everything still doesnt work . I put my old AO Smith original bearing screaming unit in FULLY primes pushes all the air out runs fine. Hi, if the spark/flame was where the plug meets the cord, it could be a plug problem or an outlet problem. Can you manually get it to rev-up on a higher speed? 3 No air bubbles on my returns when not vacuuming I inspected the impeller and it looks fine except where the threads are there are tiny hairline fractions. The outer walls become thin, allowing the pipe to crimp but only under high vacuum pressure, otherwise seems normal. I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. "publisher": {
Dont let pool pump problems drive you crazy! Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. Hi Shannon, the bolts are spinning. This is actually the second motor in 6 months. I would look on the capacitor and order a new one online, with the same MFD number, or call some local electric motor repair shop and see if they have one available. Hi Michelle, If the pump and motor are too large and powerful for your filter size, it would create this situation. I have replaced the Aqua Rite printed circuit board and the T-Cell-9. Now if none of that advice helps, and you still cannot get the lid to go on, or seal up, I would suspect that either the lid or the housing is warped from an overheating situation, running for long periods of time without water flowing through it. Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. Do I need to do something else to get it to prime faster? You need to use a K-1766 salt test kit or a calibrated meter. I believe we have the drawing in air issue at filter, I cannot locate to purchase the o ring seal and valve cover for this model. Thanks, Hi Nancy, this is a common problem water leaking out of the backwash line, while filtering. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. Testing a Pool Pump's Capacitor If your pool pump is not starting, but instead gives a 'hum' or a 'nnngh!' Vacuum hose air leaks from splits in an old hose. Checked the circuit breaker and turned it off and on.